Gas ratings – England's Stove Works 60-TRULP User Manual
Page 4
![background image](/manuals/86058/4/background.png)
GAS RATINGS
TYPE OF GAS
→ NATURAL
L.P./PROPANE
MAX. INPUT
34,500 BTU/HR
30,000 BTU/HR
MIN. INPUT
20,000 BTU/HR
20,000 BTU/HR
MANIFOLD PRESSURE
3.5” W.C.
10” W.C.
M/FOLD PRESSURE LOW
1.0/3.5” W.C.
4.5/10.0” W.C.
MIN. INLET PRESSURE
5.0” W.C.
11.0” W.C.
MIN. SUPPLY PRESSURE
5.5” W.C.
11” W.C.
MAX. SUPPLY PRESSURE
10.5” W.C.
14” W.C.
ORIFICE SIZE
#34
#51
MINIMUM CLEARANCES TO COMBUSTIBLES
THIS APPLIANCE SHALL BE INSTALLED ON A METAL OR WOOD PANEL THAT
EXTENDS THE FULL WIDTH AND DEPTH OF THE APPLIANCE WHEN INSTALLED
ON A COMBUSTIBLE SURFACE OTHER THAN WOOD.
WARNING: WHEN USED WITHOUT FRESH AIR THIS HEATER MAY GIVE OFF
CARBON MONOXIDE, AN ODORLESS POISONOUS GAS.
OPEN A WINDOW AN INCH OR TWO FOR COMBUSTION AIR.
England’s Stove Works highly recommends the use of smoke detectors and Carbon Monoxide
detectors with any hearth product, including this unit. Follow all manufacturer’s instructions when
using smoke or Carbon Monoxide detectors.
WARNING
This appliance is equipped for (natural or propane) gas. Field conversion is
not permitted
.
England’s Stove Works highly recommends the use of smoke detectors and Carbon Monoxide
detectors with any hearth product, including this unit. Follow all manufacturer’s instructions when
using smoke or Carbon Monoxide detectors.