PROBLEM

POSSIBLE CAUSE

SOLUTION

Pilot will not stay lit.

Altitude is above 4000 ft.; ODS sensor

requirement

for

air

not

satisfied.

Altitude is too high.


Defective

thermopile.

*Replace

thermopile.


Pilot

orifice

may

be

clogged.

*Clean out pilot orifice.


Defective

valve

magnet.

*Replace

valve.


“ODS” pilot lights, but flame dies

when control knob is released.

Control knob not fully pressed in.

Press in knob completely.


Control knob not pressed in long enough.

Hold 30 sec. after pilot lights.


Manual shut-off valve not fully open.

Fully open shut-off valve.


Pilot flame not touching thermopile,
which causes it to cool and shut off
the pilot flame.

Low gas pressure.

→ *Contact

gas

supplier.


Dirty

or

clogged

“ODS”

pilot.

→ *Replace

assembly

or

service.


Thermopile

damaged.

*Replace

thermopile.


Control

valve

damaged.

*Replace

control

valve.


Flame too low.

Burner orifice clogged.

*Clean burner; replace orifice.


Orifice

is

too

small.

*Replace orifice if necessary.


Inlet

gas

pressure

too

low.

*Contact

gas

supplier.


Burner will not come on or

Problem with gas pressure.

*Check

gas

pressure.

has low flame (pilot is okay).

Control not on or is set on “LOW”.

Move to “HIGH” setting.


Gas valve may be clogged due to

debris

entering

valve

during

installation.

*Replace gas valve.


Faulty

gas

valve.

*Replace

gas

valve.


Burner will not come on or has an

Burner ports and/or carryover ports

extremely low flame (pilot okay).

may be clogged.

*Check

and

clean

ports.


Delayed ignition of burner.

Manifold pressure is too low.

*Contact gas supplier.


Burner

or

orifice

is

clogged.

*Check and clean both.


Burner backfiring during ignition.

Orifice clogged or damaged.

→ *Clean

and/or

replace.


Burner

damaged.

*Clean

and/or

replace.


Burner will not come on.

Dirt on valve seal.

*Replace

valve.


Control knob frozen – will not turn.

Defective valve; foreign material.

*Replace

valve.


Carbon or sooting on logs.

Logs out of position.

See log placement in manual.


Air holes on burner tube obstructed.

*Clean if necessary.


Gas type does not match stove.

Check designation on valve.


Oversized

orifice.

*Change

if

necessary.

LP fuel may have additives.

*Check

with

gas

supplier.

Gas pressure may be incorrect.

*Check with gas supplier.