beautypg.com

Chapter 6 troubleshooting, 1. no picture – Eizo ColorEdge CS2740 26.9" 16:9 Wide Gamut 4K IPS Monitor User Manual

Page 36

background image

36

Chapter 6 Troubleshooting

Chapter 6 Troubleshooting

6-1. No Picture

Problem

Possible cause and remedy

1. No picture

Power indicator does not light up.

Check whether the power cord is connected properly.

Turn on the main power switch on the rear side of the monitor.

• Touch

.

Turn off the main power switch on the rear side of the monitor,

and then turn it on again a few minutes later.

Power indicator is lighting white.

Increase "Brightness" and/or "Gain" in the Setting menu (see

“Color” (page 26)

).

Power indicator is lighting orange.

Switch the input signal.

Move the mouse or press any key on the keyboard.

Check whether the external device is turned on.

Turn off the main power switch on the rear side of the monitor,

and then turn it on again.

Power indicator is flashing orange and

white.

This problem may occur when an external device is

connected via the DisplayPort connector or the USB Type-C

connector. Connect via the signal cable specified by EIZO,

turn off the monitor, and then turn it on again.

2. The message below appears.

This message appears when the signal is not input correctly even

though the monitor is functioning properly.

This message appears when no signal is

input.

Example:

The message shown left may appear, because some external

devices do not output the signal immediately after power-on.

Check whether the external device is turned on.

Check whether the signal cable is connected properly.

Switch the input signal.

Turn off the main power switch on the rear side of the monitor,

and then turn it on again.

Try changing "Signal Format" in the "Administrator Settings"

menu (see

“Signal Format” (page 35)

).

The message shows that the input signal

is out of the frequency specification range.

Example:

Check whether the external device is configured to meet the

resolution and vertical scan frequency requirements of the

monitor (see

“1-3. Supported Resolutions” (page 9)

).

Reboot the external device.

Change to the appropriate setting using the graphics board's

utility. Refer to the User's Manual of the graphics board for

details.

This message appears when an external

device connected to the USB Type-C

connector does not support video signal

output.

Example:

Check whether the signal cable specified by EIZO is

connected.

Check whether the USB Type-C port of the connected

device supports video signal output. For details, contact the

manufacturer of the device.

Connect a DisplayPort cable or an HDMI cable.

This manual is related to the following products: