12 - O

PERATING FAULTS

If the conditioner is not working, there may be loss of synchronism between the appliance and the remote control.

Synchronising procedure:
- Remove the conditioner housing upper cover (4 screws) (1).

- To turn on the remote control, press and hold down the

key for about 8 seconds, until the

indicator goes off.

- Place the switch, located under the conditioner, in position 1.The green LED on the board comes on (2).

- Press and hold down the On/Off button (brown button) on the board for more than 6 seconds, then release (3).The green LED will then start to flash

(synchronising mode).

- Simultaneously press the

and

keys on the remote control until ! is displayed

.

- As soon as the green LED on the board stops flashing (end of synchronising mode), the conditioner and remote control are then synchronised.

- Exit "RF" mode by pressing the

key on the remote control.

(1)

(2)

(3)

On/ off button

Green LED

11 - M

AINTENANCE

It is necessary to thoroughly clean the conditioner’s internal elements every year.

- Unplug the appliance.

- Place the appliance on the ground to disassemble it (4 screws).

- Vacuum the 4 air entry and exit grids.

- Remove the upper cover (2 screws) (1).

- Snap off from the top the 2 columns in order to access the 8 screws of the 2 front sections (2).

- Disassemble the front sections by removing the screws (square end pieces, not supplied).

- Thoroughly clean the ribs of the 2 exchangers with a vacuum cleaner (3).

- Repeat these instructions in the opposite order to reassemble the appliance.

(1)

(2)

(3)

Ribs of the

2 exchangers