After sales department, Subject: inoa-technical datas and tubing – Eurocave INOA 50 User Manual
Page 13

AFTER SALES DEPARTMENT
TECHNICAL NOTE N° 031
Date : 15/11/10
Revision : 0
Page : 1 of 2
Subject: INOA-TECHNICAL DATAS AND TUBING
Extraction kit: AEVACLM or PEVACLM (not supplied with the air conditioner, option
to be ordered), one kit per hole.
Technical datas: INOA 230 V 50 Hz
INOA25
INOA50
Maximum volume of the wine cellar
25 m3
50 m3
Cooling power
600 W
1200 W
Maximum distance for the remote control
10 m
10 m
Quantity of speeds for the condenser fan
4
4
Quantity of speeds of the evaporator fan
3
3
Condenser fan air flow (per speed : 1, 2, 3, 4) in m3/h
230, 335,
431, 563
273, 353,
473, 682
Evaporator fan air flow (per speed : 1, 2, 3) in m3/h
199, 285,
382
227, 352,
445
Gas load in R134a
400 grs
400 grs
Pressures BP and HP for 35°c (in bar)
2,3 ; 11,2
2,1 ; 10,5
Type of gas reducer
Capillary
Capillary
Condenser gas temperature
47°c
45°c