Cabling: rear side, Xlr inputs and outputs, Db25 in and output connectors – SPL Hermes Mastering Router with Dual Parallel Mixes (Red) User Manual

Page 9: Ground lift switch to avoid ground loops

background image

7

Cabling: Rear Side

XLR inputs and outputs

We used exclusively Switchcraft/Neutrik XLR input and output plugs to guarantee perfect
connectivity in the studio. They provide an optimal connection thanks to their electrome-
chanical design and large contact surface.

The image shows the XLR connectors pinout. They are balanced and have three conduc-
tors or wires. Conductor 2 (Pin 2) corresponds to the (+) or hot Signal.

In case an unbalanced connection is necessary, the correct polarity of the conductors
needs to be observed.

DB25 in and output connectors

The image shows the assignment of the DB25 connectors. The pin assigment corresponds
to Tascam standard, (AES/EBU). The inputs (Returns) are located on positions 1-4. The
outputs (Sends) on positions 5-8.

Ground Lift switch to avoid ground loops

On the rear panel of the Hermes Mastering Router (see page 8) is also a „GND LIFT“
(Ground Lift) switch to avoid any ground loops. Ground loops take place when gear con-
nected in the same network have different potentials

The GND LIFT switch disconnects the equipment ground from the service ground to avoid
such problems. The Ground Lift function is activated (= equipment ground disconnected)
when the switch is depressed.

1

14

13

25

GCHGCH

Returns

Sends

GCHGCHGCH GCH GCH GCH

1

2

3

4

1

2

3

4

G=GROUND (GND), C=COLD (-), H=HOT (+)