beautypg.com

Amp ctl, Power led en, Amp ctl (standby / amplifier control) – SPL Performer m1000 Mono Power Amplifier (Red) User Manual

Page 16: Power led, I f r

background image

16

AMP CTL (Standby / Amplifier Control)

If you own an SPL device supporting AMP CTL output(s) you can trigger standby and
operation. Therefore connect the AMP CTL output of the SPL device with a mono mini
jack cable to the

AMP CTL (10)

of the Performer m1000.

You may also use other 12V trigger controller. The Performer m1000 is in operation
mode when a switching voltage of 12 Volt DC is applied to the AMP CTL input.
As soon as the 12 Volt DC is removed, the Performer m1000 switches back to
standby mode.
Use a mono mini jack cable where the tip is plus and the sleeve is minus.

Power LED

In standby the Power LED is dimly lit.

If the Performer m1000 is in operation, the Power LED lights up brightly.

If the Performer m1000 is off, e.g. the mains switch is off, the Power LED is off.

XLR WIRING:
Pin 1 = GND

Pin 2 = Hot (+)

Pin 3 = Cold (–)

Minimum Load:

2

Ω

INPUT

THRU

INPUT

TRIM

INPU

T

AM

P CTL/

12V T

RIG

GER

SPE

AKE

R OUT

PUT

SPEAKER OUTPUT

+

AMP CTL/12V TRIGGER

Connect to

SPL devices

supporting

AMP CTL

for remote

standby on/off.

0 -5.5

-5

-4

.5

-4

-3.5

- 3

-2

.5

-2

-1

.5

-1

-0.5

Tip
Sleeve

I F R