Controlling the Monitor with a PC (RS-232C)

Setting of the GAMMA user data

n

To transfer the GAMMA user data

Use the user data transfer commands (UGRW, UGGW and

UGBW). For each of the R, G and B colors, divide the total

512 pieces of user data into 16 blocks, and transfer 32 pieces

of data with each command.

C1 C2 C3 C4 P1 P2 P3 P4

… S1 S2

Command field Block number (01 to 16) Data field Checksum field

Example: To transfer the data of block 1 (0 to 31 levels)

of red (R) data

UGRW01000000010002 … 0031C0

Command Block number 32 pieces of data

Checksum

One piece of data consists

of 4 digits.

* If data is less than 4 digits, add a “0” (zero) to make it 4

digits.

* The checksum field is the character string (ASCII) data of

lower-order one byte which indicates the sum of the block

number and 32 pieces of data in hexadecimal (0 to F).

n

Saving the GAMMA user data

Use the user data save command (UGSV) to save the

transferred user data in the monitor.

If the data is not saved, it will be cleared when:

• The main power switch is off

• POWER SAVE MODE is ON and the monitor enters

standby mode

n

Activating the GAMMA user data

To activate the transferred user data, select USER for GAMMA

of the PICTURE menu, or send the corresponding RS-232C

command.

n

Checking the GAMMA user data

Use the user data read commands (UGRR, UGGR and

UGBR) to return 512 pieces of user data for each of the R,

G and B colors. Divide the data into 16 blocks and return 32

pieces of data with each command. The value to be returned

is not the value stored in the monitor, but the value in the

temporary memory for display. (These values are the same

when the user data save command (UGSV) above has been

sent.)

TIPS

• The user data is not initialized by RESET of the PICTURE

menu. To initialize the user data, use ALL RESET of the

FUNCTION menu.

The GAMMA user data initialize command (UGRS) allows

the initialization of the user data only.