Specifications, Dimensions, Clearances to combustibles – Enviro EG28 DV User Manual
Page 5: Preparation for installation
5
WARNING:
Operation of this heater when not connected to a properly installed and maintained venting system can result in
carbon monoxide (CO) poisoning and possible death.
Specifications
D
IMENSIONS
:
���
���� ���
���
���� ���
���
���� ���
��
���� ���
��
�
�
�
�
���� ���
�������� ������ ��� ��� ��� ���
C
LEARANCES
TO
C
OMBUSTIBLES
:
A. Sidewall to unit
10 inches (25.4 cm)
B. Backwall to unit
4 inches (10.2 cm)
C. Corner to unit
2 inches (5.1 cm)
D. Combustibles to unit top 22 inches (55.9 cm)
E. Floor to unit
0 inches
F. Alcove maximum depth:
48 inches (121.9 cm)
• Locate a position where the flue system of the stove can
be properly installed without damaging the integrity of the
building; e.g. cutting a wall or ceiling joist.
• Check stove and flue system clearance requirements.
• Locate the stove where it can be accessed by a gas supply line.
• Locate the stove in a large and open room that is centrally located in the house. This will optimize heat circulation
and comfort.
• As the stove is equipped with a convection fan, ensure that an electrical outlet is within 6 feet. (1.8 m) of the
stove.
• The flow of combustion and ventilation air must not be obstructed.
CLEARANCES MUST BE SUFFICIENT TO ALLOW ACCESS FOR MAINTENANCE AND SERVICE.
P
REPARATION
F
OR
I
NSTALLATION
:
• Remove the packaging from the appliance, and check to make sure there is no damage. If damage is found,
please report it to both the carrier and your dealer as soon as possible.
• Before beginning, carefully check the glass door and the log set
Figure 1: EG28 Exterior Dimensions.
���
���� ���
��
��� ���
��
���� ���
Figure 2: Clearances to combustibles.