INSTALLATION INSTRUCTIONS:

1. Decide on a location for the unit that will meet any or all local code requirements. Refer “Planning Your

Installation” and “Clearances to Combustibles”.

2. Set the appliance in the desired location. Determine if any wall studs, electrical wiring, or plumbing pipes are

in the way of the venting system as it passes through the wall. If obstructions are found in the wall it may be

necessary to adjust the location of the appliance.

3. Set the appliance in the desired location. Temporarily place a 24” (61 cm) section with the non-crimped end on

the unit

4. Install the 90° elbow onto the vertical pipe on the stove pointing in the direction that the vent will exit the

structure.

5. Project a level line from the center point of the elbow. Using this center point, scribe

a 10” (25.4 cm) hole or square on the wall. Cut the hole out on both the interior and

exterior wall surface.

6. Frame the hole as shown in Figure 9.
7. Install the wall thimble and secure the thimble to the inner wall surface.
8. With the appliance still in place install the 24” (61 cm) horizontal section on the

elbow and let this section of pipe protrude through the exterior surface. Mark the

pipe so that when it is cut it will be flush with the exterior wall.

9. Dismantle the outer pipe sections.
10. Remove the 4” (10 cm) flue collar from the unit and remove any loose sealant. Install

the new Ø 4” (10 cm) by 5” (12.5 cm) flue collar provided in this kit

.

11. Stretch the liner out. Attach the flexible liner to the vent termination cap by placing

a small bead of high temperature silicone on the vent termination and slide the flex

liner onto the vent terminal and secure with three (3) sheet metal screws evenly

spaced.

12. Dress the flex liner through the wall thimble and attach the vent terminal to the

outside of the house using four (4) wood screws provided. The use of non-hardening

mastic should be used around the vent to ensure a watertight seal.

13. Install two (2) wire spacer around the flex pipe. Slide the horizontal section of pipe over the flexible liner. Ensure

the wire spacers are positioned at either end of the pipe (refer to Figure 21 and 22).

14. Install the horizontal section of pipe through the wall thimble, ensure

that this portion of pipe slides onto the vent termination cap.

15. Slide the inside finished collar over the horizontal section of pipe and

secure to wall using the screw provided.

16. Slide the 90° elbow over the flex pipe. Do not slip the outer

sections of pipe together, you will require some movement

in these pipe section in order to secure the flex pipe to the

flue outlet on the appliance.

17. Stretch the flex liner to a length long enough to ensure the flex liner

can be easily connected to the flue outlet of the appliance.

18. Install the remaining wire spacers over the flexible liner and install

the vertical section of pipe. Ensure the wire spacers are positioned

at either end of the pipe (refer to Figure 21 and 22).