Yamaha CVP-705B User Manual
Page 47
CVP-709/CVP-705/CVP-701 MIDI Reference
MIDI Data Format / MIDI-Datenformat / Format des données MIDI / Formato de datos MIDI
47
Channel Pressure (Aftertouch)
F0 7F XN 09 01 0M PP RR … F7
[GM2]
11110000 F0 = Exclusive status
01111111 7F = Universal Real Time
0xxxnnnn XN = When N is received N=0-F, whichever is received. X=ignored
00001001 09 = Sub-ID #1= Controller Destination Setting
00000001 01 = Sub-ID #2= Controller Type: 01 (Channel Pressure)
0000mmmm 0M = MIDI Channel (00-0F)
0ppppppp PP = Controlled Parameter
0rrrrrrr RR = Data
…
…
11110111 F7 = End of Exclusive
Make sure to set both the controlled parameter and the range.
Parameters not set will be restored to their default values.
Control Parameter (pp)
Data (RR) Description
Default Value
----------------------------------------------------------------------------------
pp=00 Pitch Control
28H-58H -24…0…+24semitones 40H
pp=01 Filter Cutoff Control 00H-7FH -9600…0…+9450cents 40H
pp=02 Amplitude Control
00H-7FH -100…0…+100%
40H
pp=03 LFO Pitch Depth
00H-7FH 0…127
00H
pp=04 LFO Filter Depth
00H-7FH 0…127
00H
pp=05 LFO Amplitude Depth 00H-7FH 0…127
00H
Controller (Control Change)
F0 7F XN 09 03 0M CC PP RR … F7
[GM2]
11110000 F0 = Exclusive status
01111111 7F = Universal Real Time
0xxxnnnn XN = When N is received N=0-F, whichever is received. X=ignored
00001001 09 = Sub-ID #1 = Controller Destination Setting
00000011 03 = Sub-ID #2 = Controller Type: 03 (Control Change)
0000mmmm 0M = MIDI Channel (00-0F)
0ccccccc CC = Controller Number (01H-1FH, 40H-5FH)
0ppppppp PP = Controlled Parameter
0rrrrrrr RR = Range
…
…
11110111 F7 = End of Exclusive
Make sure to set both the controlled parameter and the range.
Parameters not set will be restored to their default values.
Control Parameter (pp)
Data (RR) Description
Default Value
----------------------------------------------------------------------------------
pp=00 Pitch Control
28H-58H -24…0…+24semitones 40H
pp=01 Filter Cutoff Control 00H-7FH -9600…0…+9450cents 40H
pp=02 Amplitude Control
00H-7FH -100…0…+100%
40H
pp=03 LFO Pitch Depth
00H-7FH 0…127
00H
pp=04 LFO Filter Depth
00H-7FH 0…127
00H
pp=05 LFO Amplitude Depth 00H-7FH 0…127
00H
Key-Based Instrument Control
F0 7F XN 0A 01 0M KK CC VV … F7
(Drum only)
[GM2]
11110000 F0 = Exclusive status
01111111 7F = Universal Real Time
0xxxnnnn XN = When N is received N=0-F, whichever is received. X=ignored
00001010 0A = Sub-ID #1 = Key-Based Instrument Control
00000001 01 = Sub-ID #2= Controller
0000mmmm 0M = MIDI Channel (00-0F)
0kkkkkkk KK = Key Number
0ccccccc CC = Controller Number
0vvvvvvv VV = Value
…
…
11110111 F7 = End of Exclusive
Make sure to set both the controlled parameter and the value.
Control Number (CC)
Value (VV) Description
Default Value
----------------------------------------------------------------------------------
CC=07H Volume
00H-7FH
-100…0…+100% 40H
CC=0AH Pan
00H-7FH
-L63…C…R63
(Preset value)
(absolute)
CC=5BH Reverb Send Level 00H-7FH
0…Max
(Preset value)
(absolute)
CC=5DH Chorus Send Level 00H-7FH
0…Max
(Preset value)
(absolute)
[MIDI]
[Internal Sequencer]
MIDI Event
Data Format
Voice
MIDI Reception
MIDI Transmission
PLAY
REC
Regular/
Drum/
Natural/
Organ
Voice
Mic/
Vocal
Harmony
Song
CVP-705/
709: Main/
Layer/Left
CVP-701:
Right1/
Right2/Left
Keyboard
Style
Extra
CVP-705/
709: Main/
Layer/Left
CVP-701:
Right1/
Right2/Left
Style
Song
Upper
Lower
PLAY
REW
From panel