6 Reference

In This Chapter

™ Memory Map .........................................................................................21

™ Cable Connections ................................................................................ 21

6.1 Memory

Map

Address
(hexadecimal)

Size
(Kbytes)

Function

000000 to 09FFFF

640

System RAM

0A0000 to 0AFFFF

64

VGA Video Graphics RAM

0B0000 to 0BFFFF

32

VGA Enhanced Mode Graphics RAM

0B8000 to 0BFFFF

32

VGA Text RAM

0C0000 to 0CBFFF

48

VGA BIOS

0CC000 to CFFFFF

16

Free Memory

0D0000 to 0DFFFF

64

Free Memory when ControlLogix

®

configuration jumper is set

to 32 bit position.

64 Kbyte allocated by PCI BIOS for dual port memory when
ControlLogix

®

configuration jumper is set to 16 bit position.

0E0000 to 0EFFFFF

64

System BIOS

0F0000 to 0FFFFF

64

System BIOS

0100000 to 07FFFFFF 1 to 128

Mbyte

System Extended Memory

080000000 to
0C0000000

2 GByte to
3 GByte

Used to map memory windows requested by PCI peripherals

6.2 Cable

Connections

The application ports on the PC56 module support RS-232, RS-422, and RS-485
interfaces. Please inspect the module to ensure that the jumpers are set correctly
to correspond with the type of interface you are using.

Note: When using RS-232 with radio modem applications, some radios or modems require
hardware handshaking (control and monitoring of modem signal lines). Enable this in the
configuration of the module by setting the UseCTS parameter to 1.