Question:
Is PC56 slot dependent?
Answer:
No, but some consideration should be given to making room for any peripheral
modules you are plugging onto the PCI bus.
Question:
Does the order I plug the PC56 peripherals on to the PCI bus matter?
Answer:
The PC56-IDE module, if used, should always be installed in the first slot to the
left of the PC56 (Slot 0). Slot locations are numbered 0 through 2 starting at the
first slot location to the left of the PC56. The PCI slot assignment jumper for each
PCI peripheral module should be installed to match its corresponding physical
slot location.
Question:
What is the maximum number of peripheral PCI modules I can plug onto PC56?
Answer:
Three unless otherwise specified.