beautypg.com

Excell Precision E7540 User Manual

Page 15

background image

15-ENG

A18791

6. Run the compressor for 20 minutes. Make sure the globe valve is open and

there is minimal air pressure build-up in tank.

7. Check all air line fittings and connections/piping for air leaks by applying a

soap solution. Correct if necessary. NOTE: Minor leaks can cause the air
compressor to overwork, resulting in premature breakdown or inadequate
performance.

8. Check for excessive vibration. Readjust or shim air compressor feet, if nec-

essary.

9. After 20 minutes, close the globe valve. The air receiver will fill to "cut-out"

pressure and the motor will stop.

Before Each Start-Up:

1. Place On/Auto/Off lever to "Off".

2. Close the globe valve.

3. Attach hose and accessories. NOTE: A regulator MUST be installed when

using accessories rated at less than 175 PSI.

NOTE: The hose or accessory will require a quick connect plug if the air outlet
is equipped with a quick connect socket.

Risk of Bursting. Too much air pressure causes a hazard-
ous risk of bursting. Check the manufacturer’s maximum

pressure rating for air tools and accessories. The regulator outlet pressure
must never exceed.

How to Start:

1. Turn the On/Auto/Off lever to "On/Auto" and allow tank pressure to build.

Motor will stop when tank pressure reaches "cut-out" pressure.

2. When the tank pressure reaches "cut-out" pressure open the globe valve.

IMPORTANT: When using regulator and other accessories refer to the manufac-
turers instructions.

The compressor is ready for use.