Avago Technologies AcceleRAID 160 User Manual
Page 17

Hardware Installation
Manual No. DB11-000021-00
5
Installing the AcceleRAID 160 into a Standard Chassis
If your system has a 2U chassis, please go to “Installing the AcceleRAID
160 into a 2U Chassis” on page 9.
Caution
Be sure to wear a ground wrist strap at all times.
☛
Note
If the controller has the Low Profile Bracket attached,
replace it with the Standard PCI bracket for this
installation.
1. With the power off, plug the AcceleRAID 160 controller into an
available 32-bit PCI slot on the system board (see Figure 5); the 32-bit
slot is short.
Figure 5. Plugging the AcceleRAID 160 into a PCI Slot
2. Set the SCSI ID on each internal drive to a unique address between
0 and 15, but do not use address 7, as it is reserved for the controller.
See the documentation that comes with your drives for instructions on
how to set the SCSI ID address.
Caution
If internal and external drives are used, be sure that
drive addresses are NOT duplicated. External SCSI
cabinets usually automatically assign drive addresses
according to the drives’ location in the cabinet.
Ground Clip
Ground
Wrist
Strap
AcceleRAID
160
32-bit PCI