beautypg.com

Avago Technologies MegaRAID SCSI 320-2X (532) User Manual

Page 2

background image

2 of 4

The following table lists the jumpers and connectors on the
MegaRAID 320-2X controller.

Step 4

Check the Memory Module.

Ensure that the memory is present and seated
firmly in the DIMM socket.

Note:

For more information about supported memory,
contact Technical Support. Refer to the
Technical Support section in this document for
contact information.

Step 5

Install the RAID Controller.

Install the MegaRAID 320-2X in a 3.3 V PCI or
PCI-X slot, as shown in

Figure 2

. Press down

gently, but firmly, on the top edge of the card to
seat the card properly in the slot. The bottom
edge of the controller card must be flush with the
slot. Attach the MegaRAID 320-2X to the
computer chassis with the bracket screw.

If your board has a memory module, never apply
pressure to the module when inserting the adapter
.
Applying pressure could break the module.

Figure 2 Installing the MegaRAID 320-2X Board

Step 6

Connect SCSI Devices to the RAID Controller.

Connect the SCSI devices to the internal,
high-density, 68-pin SCSI connectors (J5 and J6)
and/or the external, very high-density, 68-pin

Item Connector

Description

J1

Termination
Enable
Channel 0

3-pin header.

Jumper pins 1–2 for software to use drive
detection to control SCSI termination
(default; do not change).
Jumper pins 2–3 to disable onboard SCSI
termination.
No jumper means onboard SCSI termination
is enabled.

J2

Termination
Enable
Channel 1

3-pin header.

Jumper pins 1–2 for software to use drive
detection to control SCSI termination
(default; do not change).
Jumper pins 2–3 to disable onboard SCSI
termination.
No jumper means onboard SCSI termination
is enabled.

J5

Internal SCSI
Channel 0
Connector

68-pin connector.

Internal, high-density SCSI bus connector.
Connection is optional.

J6

Internal SCSI
Channel 1
Connector

68-pin connector.

Internal, high-density SCSI bus connector.
Connection is optional.

J7

External SCSI
Channel 0
Connector

68-pin connector.

External, very high-density SCSI bus
connector.
Connection is optional.

J11

Onboard
Cache LED

2-pin header.

The LED glows when the onboard cache
contains data and a write from the cache to
the hard drives is pending.

J12

BBU
Daughtercard

40-pin header.

Connector for optional backup battery pack.

J13

SCSI Activity
LED

2-pin header.

Connector for enclosure LED to indicate
data transfers.
Connection is optional.

J14

External SCSI
Channel 1
Connector

68-pin connector.

External, very high-density SCSI bus
connector.
Connection is optional.

J17

Termination
Power Enable
Channel 0

2-pin header.

Jumper pins 1–2 to supply termination power.
No jumper means SCSI bus provides
termination power.

J18

Termination
Power Enable
Channel 1

2-pin header.

Jumper pins 1–2 to supply termination power.
No jumper installed means the SCSI bus
provides termination power.

J19

Onboard BIOS
Enable

4-pin header (2 rows of 2 pins each).

No jumper installed enables BIOS (default;
do not change).
Jumper pins 2/4 to disable BIOS.

U6

Dual Inline
Memory Module
(DIMM) Socket

The MegaRAID 320-2X supports
512 Mbytes of 100 MHz double data rate
(DDR) error correcting code (ECC) SDRAM.

!

CAUTION

64-Bit Slots

(3.3 V)

Bracket
Screw

Press

Here

Press

Here