5.6

Thermal and Atmospheric Limits

The atmospheric limits for the LSI 12Gb/s SAS HBA are as follows:

Temperature range: 0 °C to 55 °C (32 °F to 131 °F) (dry bulb)

Relative humidity range: 5% to 90% noncondensing

Maximum dew point temperature: 32 °C (89.6 °F)

Minimum airflow: 200 linear feet per minute

The following limits define the storage and transit environment for the LSI 12Gb/s SAS HBA:

Temperature range: –45 °C to +105 °C (–49 °F to +221 °F) (dry bulb)

Relative humidity range: 5% to 90% noncondensing

6

LSI 12Gb/s SAS HBA Certifications and Safety Characteristics

All LSI 12Gb/s SAS HBAs meet or exceed the requirements of UL flammability rating 94V-0. Each bare board is marked
with the supplier’s name or trademark, type, and UL flammability rating. Because these boards are installed in a PCIe
bus slot, all voltages are less than the SELV 42.4-V limit.

The design and implementation of the LSI 12Gb/s SAS HBA minimizes electromagnetic emissions, susceptibility to
radio frequency energy, and the effects of electrostatic discharge.

The LSI 12Gb/s SAS HBA meets the following integrated electromagnetic interference (EMI) compliance labels:

CE mark

CISPR Class B

C-Tick mark

Canadian Compliance Statement

FCC Class B, marked with the FCC Self-Certification logo

Japan VCCI

Korean KCC

Taiwan BSMI

The LSI 12Gb/s SAS HBA meets the following environmental directives:

RoHS

WEEE

7

Hardware Detailed Installation Instructions

To install the LSI 12Gb/s SAS HBA, follow these steps:

1.

Unpack the HBA, and inspect it for damage. Unpack the HBA in a static-free environment. Remove the HBA
from the antistatic bag, and carefully inspect the device for damage. If you notice any damage, contact LSI or your
reseller support representative.

ATTENTION

To avoid the risk of data loss, make a backup of your data before
changing your system configuration.