beautypg.com

4 physical characteristics, 5 power requirements, 6 thermal and atmospheric limits – Avago Technologies SAS 9206-16e Host Bus Adapter User Manual

Page 6

background image

Avago Technologies

- 6 -

LSI SAS 9206-16e PCI Express to 6Gb/s SAS HBA User Guide

October 2014

LSI SAS 9206-16e HBA Characteristics

5.4

Physical Characteristics

The LSI SAS 9206-16e HBA is a 6.6-in. x 2.7-in., low-profile board. The component height on the top and bottom of the
LSI SAS 9206-16e HBA is in accordance with the PCIe specification. The following figure shows the board layout.

Figure 1 LSI SAS 9206-16e HBA Board Layout

J2B1: PCIe x8-lane board edge connector

J1A2: SFF-8644 mini-SAS HD, external connectors

CR4B1 and CR5B1: Heartbeat LEDs

5.5

Power Requirements

The maximum power requirements for the LSI SAS 9206-16e HBA under normal operation are as follows:

PCIe 3.3 V = 0.83 A

PCIe 12.0 V = 1.92 A

Passive cable, nominal = 25.8 W

5.6

Thermal and Atmospheric Limits

The atmospheric limits for the LSI SAS 9206-16e HBA are as follows:

Temperature range: 0 °C to 55 °C (32 °F to 131 °F) (dry bulb)

Relative humidity range: 5 percent to 90 percent noncondensing

Maximum dew point temperature: 32 °C (89.6 °F)

Minimum airflow:

100 linear feet per minute at 35 °C (95 °F) bay inlet temperature

150 linear feet per minute at 45 °C (113 °F) bay inlet temperature

200 linear feet per minute at 55 °C (131 °F) bay inlet temperature

NOTE

LSI developed airflow limits in a flow tube with ideal airflow. Your
server model might require different limits.

*"

?

,3)3!3

,3)3!3

0ORT

*!

#2"

#2"