Technical Data

Display:

3 digit LCD, 1999 digit

Duration of measurement:

3-5s

Measurement principle:

current-voltage measurement principle in accordance with
EN61557-5

Measurement voltage:

25V/ 50V selection

Current/power consumption: approx. 10mA/ 0,1W max. 500mA briefly, during measurement
Measurement current:

max. 12mA

Frequency (f1/ f2):

127Hz/ 140Hz, selectable

Measurement method:

2 pole/ 3 pole/ 4 pole
Range

Tolerance

RE:

0.05 - 2.00 Ohm ±(4% + 0.1 Ohm)

±(6% + 0.1 Ohm)*

RE:

2.00 - 1999 Ohm ±(4% + 2 Digit)

±(6% + 3 Digit)*

RH, RS:

0.1 - 50 kOhm

±(10% + 3 Digit)*

IM:

0.1 - 13mA

±(10% + 3 Digit)*

*operating error

Nominal use range:
Correct polarity:

for 3/4 pole measurements

Noise voltage:

0...5V, max. 10% of measurement voltage

aux. earth (RH), probe resis. (RS):

max. 50 kOhm

Ratio RH/ RE:

max. 1000/1

Ratio RS/ RE:

max. 10000/1

Earth resistance (RE):

max. 2 kOhm

Reference range:
Correct polarity:

for 3/4 pole measurements

Noise voltage:

0 V

aux. earth (RH),
probe resis. (RS)

0 Ohm

Earth resistance (RE):

max. 2 kOhm

Auto power off

after approx. 5 min

Power supply

6 x 1.5 V Type IEC LR6 (Mignon/Size AA)

Low Bat at

6.6 V ±5 % (OFF at 6.1V ±5 %)

Battery life

approx. 1 year for normal use

Dimensions (LxWxD)

235x105x68 mm

Weight

approx. 640g (inc. 6 x batteries)

22

PAEB30872261:Layout 1 12.12.2007 12:06 Uhr Seite 22