Figure 5

The gas pipeline can be brought in through the right or left side of

the appliance. The insert has a Flexline with shutoff valve located

on the right side when facing the unit. See Figures 5 and 6. Consult

the current National Fuel Gas Code, ANSI Z223.1 CAN/CGA-B149

(.1 or .2) installation code.

Installing the Main Gas Cock

Each appliance should have its own manual gas cock.

A manual main gas cock should be located in the vicinity of the

unit. Where none exists, or where its size or location is not ad-

equate, contact your local authorized installer for installation or

relocation.

Compounds used on threaded joints of gas piping shall be resistant

to the action of liquefied petroleum gases. The gas lines must be

checked for leaks by the installer. This should be done with a soap

solution watching for bubbles on all exposed connections, and if

unexposed, a pressure test should be made.
Never use an exposed flame to check for leaks. Appliance must

be disconnected from piping at inlet of control valve and pipe

capped or plugged for pressure test. Never pressure test with

appliance connected; control valve will sustain damage!
NOTE:
The millivolt gas controls are equipped with a captured

screw type pressure test point, therefore it is not necessary to provide

a 1/8" test point up stream of the control.
When using copper or flex connector use only approved fittings.

The appliance and it’s individual shut off valve must be disconnected

from supply piping system during any pressure testing of that system

at test pressures in excess of 1/2 psig (3.5kPa).

The appliance must be isolated from the gas supply piping system

by closing its individual manual shut off valve during any pressure

testing of the gas supply piping system at test pressures equal to or

less than 1/2 psig (3.5kPa).

Attention! If one of the procedures results in pressures in excess

of 1/2 psig (14" w.c.) (3.5 kPa) on the fireplace gas valve, it will

result in a hazardous condition.
Checking Manifold Pressures

Both Propane and Natural gas valves have a built-in pressure

regulator in the gas valve. Natural gas models will have a manifold

pressure of approximately 3.5" w.c. (.871kPa) at the valve outlet

with the inlet pressure to the valve from a minimum of 4.5" w.c.

(1.120kPa) for the purpose of input adjustment to a maximum of

14.0" w.c. (3.484kPa). Propane gas models will have a manifold

pressure approximately 10.0" w.c. (2.49kPa) at the valve outlet

with the inlet pressure to the valve from a minimum of 10.8" w.c.

(2.68kPa) for the purpose of input adjustment to a maximum of

14.0" w.c. (3.484kPa).

Gas Supply Pressure (inches w.c.)
Minimum Normal

Maximum

Natural Gas

4.5"

7.0"

14.0"

LP (Propane)

10.8"

11.0"

14.0"

Manifold Pressure (inches w.c.)

Normal (HI)

Natural Gas

3.5"

LP (Propane)

10.0"

Note: Never use plastic pipe. Check to confirm whether your

local codes allow copper tubing or galvanized.

Note: Since some municipalities have additional local codes, it is

always best to consult your local authority and installation code.
The use of the following gas connectors is recommended:
— ANS Z21.24 Appliance Connectors of Corrugated Metal Tubing

and Fittings.

— ANS Z21.45 Assembled Flexible Appliance Connectors of

Other Than All-Metal Construction

The above connectors may be used if acceptable by the authority

having jurisdiction. The state of Massachusetts requires that a flexible

appliance connector cannot exceed three feet in length.

Recommended Gas Pipe Diameter

Pipe Length

Schedule 40 Pipe

Inside Diameter

Tubing, Type L

Outside Diameter

Nat.

L.P.

Nat.

L.P.

0-10ft

0-3m

1/2"

12.7mm

3/8"

9.5mm

1/2"

12.7mm

3/8"

9.5mm

11-40ft

4-12m

1/2"

12.7mm

1/2"

12.7mm

5/8"

15.9mm

1/2"

12.7mm

41-100ft

13-30m

1/2"

12.7mm

1/2"

12.7mm

3/4"

19mm

1/2"

12.7mm

101-150ft

31-46m

3/4"

19mm

1/2"

12.7mm

7/8"

22.2mm

3/4"

1.9 mm

GAS SUPPLY

GAS FLEX LINE WITH

SHUTOFF VALVE

(PROVIDED)

FRONT OF

INSERT

RIGHT SIDE OF INSERT

Figure 6