The SW116 wall control transmits the command
signals via radio waves to the SW105 receiver
installed in the ceiling fan ceiling cover. The
SW105 receiver is required for the SW116 wall
control to function. Power for the SW116 wall
control comes from the 12V battery, located in the
wall control.

Replacement 12V batteries recommended are
Duracell MN21, Eveready A23, and GP23A.

1. Install the 12V battery (supplied) into the wall

control (Figure 23).

2. The SW116 wall control is supplied with a white or

almond color cover. Choose the style that best
suits your needs and snap the cover onto the wall
control (Figure 23).

3. Install the wall control onto the outlet box using the

supplied screws (Figure 24).

4. Install decorator faceplate (included) using the two

screws provided. Leave wall control in “OFF” mode
until fan installation is completed (Figure 24).

12V BATTERY

WALL
CONTROL
COVER

SW116
WALL
CONTROL

HI

HI

MED

MED

LOW

LOW

FAN OFF

REV

REV

EMERSON

D/L

D/L

U/L

U/L

Setting Operating

Frequency of Wall Control

and Receiver

(Figure 22)

Your wall control and receiver have code switches
which must be set in one of 16 possible code
combinations. The four levers (numbered 1, 2, 3, and
4) on the switches are factory-set in the ON (up)
position. Change the switch settings as follows:

1. Slide the four switch levers in the wall control to

your choice of ON (up) or down positions. Use a
ball-point pen or small screwdriver and slide the
levers firmly up or down.

2. In the receiver, slide the four switch levers to the

same positions as set in the wall control. Make
sure the levers on both switches are in the same
positions, otherwise the fan will not operate.

ON

1

2

3

4

RECEIVER SWITCH
LEVERS

CODE
SWITCH

SW105 RECEIVER

CODE
SWITCH

SW116 WALL
CONTROL

WALL CONTROL
LEVERS

ON

1

2

3

4

HI

HI

MED

MED

LOW

LOW

FAN OFF

REV

REV

D/L

D/L

U/L

U/L

Figure 22

Figure 23

SW116 WALL CONTROL

DECORATIVE
FACEPLATE

OUTLET BOX

FACEPLATE
SCREW (2)

WALL CONTROL
SCREW (2)

U/L

D/L

HI

MED

LOW

FAN OFF

REV

EMERSON

Figure 24

Turning off wall switch is not sufficient. To avoid
possible electrical shock, be sure electricity is
turned off at the main fuse or circuit breaker box.

WARNING

!

Battery Installation