Timing Parameters - AC Electrical Characteristics

(VCC=VDD1=3.3V, VDD2 = 10V, GND = VSS1 = VSS2 = 0V, Ta=25ºC)

Item

Symbol

Min.

Typ.

Max.

Unit

CLK Frequency

F

CLK

25

40

MHz

CLK Pulse Width

T

CPH

25

ns

Data Set-up Time

T

SU

4

ns

Data Hold Time

T

HD

2

ns

Propagation Delay of DIO2/1

T

PHL

6

10

15

ns

Time That The Last Data to LD

T

LD

1

T

CPH

Pulse Width of LD

T

WLD

2

T

CPH

Time That LD to DIO1/2

T

LDS

5

T

CPH

POL Set-up Time

T

PSU

6

ns

POL Hold Time

T

PHD

6

ns

OE Pulse Width

T

OEV

1

µs

CKV Pulse Width

T

CKV

500

ns

STV Set-up Time

T

SUV

400

ns

STV Hold Time

T

HDV

400

ns

Horizontal Display Period

T

HDP

640

T

CPH

Horizontal Period Timing Range

T

HP

800

T

CPH

Horizontal Lines Per Field

T

V

520

525

640

T

HP

Vertical Display Timing Range

T

DV

480

T

HP