beautypg.com

Appendix a, Reference information – Extron Electronics RGB 160 User Manual

Page 12

background image

RGB 160xi and RGB 164xi • Controls and Installation

Controls and Installation, cont’d

Wide

Short

1

2-14

Negative

Follow

1

The jumpers perform the following functions:

J20: Sync polarity jumper

— This jumper

adjusts the output sync polarity.

Horizontal (H) and vertical (V) sync

output can either follow input sync

polarity, or be forced to negative.

• If the jumper is placed on pins 1 and 2, output H and V

sync polarities is forced to negative.

• If the jumper is placed on pins 2 and 3, output sync

polarity follows input sync polarity; the output sync

signal’s polarity is the same as the input polarity. This is

the default setting.

J40: Vertical sync width jumper

— This jumper

adjusts the vertical sync pulse width.

Some digital display devices have very

specific requirements for incoming sync

pulse width. If no picture displays, the

picture cuts in and out, or the picture is

scrambled, try adjusting the vertical sync pulse width or

switching from ADSP™ to DDSP™.

• If the jumper is placed on pins 1 and 2, the output vertical

sync pulse is short (narrow).

• If the jumper is placed on pins 2 and 3, the output vertical

sync pulse is wide. This is the default setting.

5

.

Replace and fasten the enclosure cover, reversing step 2.