KEYBOARD COMMANDS

ULTRAVIEW PRO INSTALLATION AND OPERATIONS MANUAL

27

Keyboard commands

The following table describes the available keyboard commands. The
key sequence is a press and release of the left control key.
Commands following must be entered within 2 seconds.

Command

Key sequence

Description

OSD menu

F12

Displays on-screen menus

CPU select

ESC

List of CPUs to select

Select
computer

nnn where nnn
= computer number

Connects the KVM station to
the selected computer.

Next computer

+

Selects next sequential CPU

Previous
computer

-

Selects previous sequential
CPU.

Scan ON

S

Turns scan mode on

Scan OFF

X

Turns scan mode off

Display label

D

Turns CPU label on/off

Logoff

L

Disconnects from currently
connected computer.

Set mode

Mnn
where nn = mode
value from Table 5.

Alternate way to configure
keyboard and mouse.

Set resolution

Yn
where n = resolution
value from Table 6

Alternate way to set screen
resolution when no video is
present from a CPU..

Screen saver
time

Vnnn
where n = 0 –999 sec.

Alternate way to set screen
saver time.

Null mouse
command

N

Used to re-sync a PS/2
mouse.

Reset mouse

O (alpha O)

Resets computer’s mouse.

Reset
command

R

Resets and enables mouse
and keyboard on currently
selected computer

Max computers

Pnnn

Total ports used (all units)

Units

Unn

Number of expansion units.

Width

Wnn

Number of ports on
expansion units.

Keep

K

Saves to flash memory.

Table 6. Keyboard commands