Slave unit installation – Rose Electronics MultiVideo User Manual
Page 25

ULTRAVIEW PRO INSTALLATION AND OPERATIONS MANUAL
11
* 4 units can be cascaded using a 4-port master/16 using a 16-port master
Figure 9. Cascading units
Slave unit installation
To properly install the slave units, follow the below steps.
(See the Configure System menu section for detailed instructions)
1. Connect the KVM stations keyboard, monitor, and mouse to the
master units Monitor/Keyboard/Mouse connector using the appropriate
KVM cable.
2. Connect CPU port #1 on the master unit to the KVM connector on
Slave #1 using a DB25 to DB25 expansion cable.
(Rose Electronics part number CAB-CXVSMMnnn)
3. Connect the next sequential CPU port on the master unit to the KVM
connector on the next sequential Slave unit.
4. Connect the remaining Slave units to the master unit.
5. When all slave units are connected, call up the UltraView Pro’s “Main
configuration” menu by pressing and releasing the left control
key, then the F12 key. (See Figure 10).
6. Using the up/down arrow keys, select (highlight) “Configure system”
and press enter. The “Configure system” menu will display. (See
Figure 6)
7. Using the up/down arrow keys, select “Maximum computers” and
press enter. Enter the total possible number of computers in the
system and press enter.
MASTER
CPUs 1-8
CPUs 9-16
CPUs 17-22
KVM station
Up to 8 UltraView Pro
SLAVE #2 Slaves can be connected* SLAVE #1