Wireless Sounder Instructions

Programming the sounder

Programming the wireless sounder consists of the following 3 steps:

1. Setting communication between the receiver and the sounder
2. Setting sounder parameters
3. Testing the sounder

Step 1: Sounder/Receiver Communication Set up

The sounder must identify itself to the system's receiver by writing its ID into the
System. Perform according to the following steps:
1. Set the receiver to the Write mode.

NOTE:

In the WisDom , as first step, you need to allocate the sounder in the following programming location:
Main engineer menu> 9) Devices > 2)Sounder > 1) Allocation > Select sounder> Choose INWS1

2. Select the sounder's ID.
3. Unpack the supplied batteries
4. Insert two speaker batteries into the batteries chamber (Fig. 3).
5. Insert three Radio batteries into the batteries chamber.
6. After a squawk is heard you have 10 seconds to press on the tamper switch for at

least 3 seconds. If the sounder is successfully recognized, the system will sound a
confirmation beep and the sounder will initiate a second squawk sound.

7. Repeat the process for other sounders in the system.

Step 2: Setting the Sounder Parameters

Each sounder can be defined with different sets of parameters. The following table
describes the list of parameters of the sounder.

NOTE:

For the specific programming location of each parameter refer to the system manuals.

Adjusting the Volume

Defines the sounder sound volume for the following system modes

¾ Exit / Entry: The sound produced during Exit/Entry time (Default: 0)
¾ Alarm: The sound produced during alarm (Default: 9)
¾ Squawk: The sound produced during squawk sounds (Default: 9)

The sound volume range is between 0 (silent) to 9 (maximum volume).

Muting Tamper

This feature disables a tamper alarm from the sounder and it is recommended to be
used when replacing sounder's batteries.

NOTES:

1. An ongoing tamper alarm will not be disabled.
2. WisDom: This feature is controlled under the Engineer Menu (Quick key [9][2][5]). Tamper alarm
will be disabled during the current installation programming period.
3. Agility: This feature is controlled under the Grand Master menu. Tamper alarm will be disabled for
20 minutes.