beautypg.com

Step description 1 – RISCO Group Orbit Pro RP-296 User Manual

Page 21

background image

user manual

13

ZONE BYPASSING

Warning

: A bypassed

zone may reduce the
system's security
capability.

When an intrusion zone is not secured, the
keypad's READY LED will not light nor can the
system be readily armed.

It may be convenient to

have one (or more) of the zones in your installation
bypassed–and thus ignored by your system.


BYPASSING/ UNBYPASSING A ZONE(S)

STEP

DESCRIPTION

1

If the system is not ready, identify the violated zone as
follow:
For LED KP - the above zone(s) is identified by
noting which zone LED(s) are flashing at the keypad's
ZONES area.
For LCD KP – Enter user code followed by to
identify the violated zone(s), (scroll Up and Down with
arrow keys to view all Not ready zones)

2

To bypass such a zone(s) and cause it to be ignored by the
system:
Enter your [code] and press ( Bypass LED will be lit)
Note: If you make a mistake when entering your User Code,
the keypad will produce three short beeps. Re-enter if
necessary.

3

Enter the two digit zone number from 01 to 96
Repeating the zone number will un-bypass it (toggle action)
An additional zone(s) can be bypassed at the same time by
adding its two-digit number to the sequence.

4


When done, press .

Note:

all zones will be automatically un-bypassed when the

panel is armed and then disarmed again.

Bypass LED will turn off when arming in AWAY mode.


Example:

To bypass zones 2 and 13 using code 1234
Enter- 1-2-3-4 [BYP] 02 13 [ENTER]

To un-bypass zone 2 only using code 1234
Enter – 1-2-3-4 [BYP] 02 [ENTER]