beautypg.com

7 - hydraulic connection – MCZ Toba HYDRO 22 User Manual

Page 36

background image

34

55

55

55

55 55 55

196

91

142

146

3

4

5

6

1

2

7 - HYDRAULIC CONNECTION

HYDRAULIC CONNECTION

IMPORTANT!

The connection of the stove to the plumbing system must be carried out ONLY by specialised personnel who are

capable of carrying out installation properly in compliance with current standards in the country of installation.

The manufacturer will not be held responsible for damage to persons or property in the event of failed operation if

the aforementioned warning is not complied with.

It is important that ONLY qualified engineers are used to fit and commission the appliance in ALL cases. The installing

engineer MUST hold a QCF recognised biomass qualification. Any company using sub-contractors MUST ensure they also

hold the relevant qualifications (ONLY FOR UK).

1

SAFETY DRAIN

5

DOMESTIC COLD WATER INLET (if applicable)

2

SYSTEM REFILL

6

SYSTEM RETURN

3

SYSTEM DELIVERY

4

DOMESTIC HOT WATER OUTLET (if applicable)

IMPORTANT!!!

CLEAN THE ENTIRE SYSTEM BEFORE CONNECTING THE STOVE, IN ORDER TO REMOVE ALL RESIDUE AND DEPOSITS.

Always install shutters in the system leading to the stove so as to disconnect it from the hydraulic system in order to

carry out routine and/or special maintenance.

Connect the stove using flexible pipes.

This manual is related to the following products: