17-ALARMS

Technical Dept. - All rights reserved - Reproduction is prohibited

A13

Electronic control unit overheating

The structure is too hot because the product has been

used for too long at the maximum power or there is

poor ventilation. When the stove is sufficiently cold,

press button B on the control panel or OFF on the remote

control to cancel alarm A13. Once the alarm is cancelled,

the product can be switched on normally.

A14

Faulty air flow rate sensor

This alarm does not block the stove, just a warning is

displayed. Contact an authorised service centre to have

the component replaced.

SER

Routine maintenance alert

When this flashing message appears upon start-up

it indicates that the preset operating hours before

maintenance is due have elapsed and that an MCZ

qualified technician must be contacted for maintenance.

Exiting the alarm conditions

Follow the procedure described below to restore normal stove operation after an alarm has been triggered:

• Put selector D on the rear emergency panel on OFF for a few seconds (about 20 seconds), until the 3 digit alarm identity code

disappears. The red LED stops flashing and the sound signal is silenced by performing the steps below.

• Put selector D back in the REMOTE position, to control the operation of the stove via the remote control.

• Switch off the remote control and switch it on again if one wants to restart the stove.