Room ventilation

Room ventilation can be adjusted as desired in all 4 operating modes described above (Manual, Automatic, Timer, Eco). Simply perform

this operation: from the basic display, press key D to access the VENTILATION adjustment mode (Fig. 6). Then press key C (arrows) to set the

desired ventilation by selecting one of the 5 levels available, independent from the flame level.

The “auto” option can also be selected, which automatically links the room ventilation speed to the flame level.

In short:

flame set on 1 > ventilation set on 1; flame set on 3 > ventilation set on 3; flame set on 5 > ventilation remains set on 3 (for silent

operation as it is in automatic mode).

In products with 2 room fans (comfort air models) via key D one can scroll and set the speed of the individual fans (identified with 1 or 2

above the level bars).

NOTE: In the event a replacement remote control is purchased, if you need to change the default setting, proceed as

follows: with the remote control switched on press buttons D + E at the same time for 10 seconds (until the flashing

number appears). Press key C to select 1 or 2 according to the product to which the remote control is to be paired, and

press E to exit.

IMPORTANT! Choosing the right number of fans can become a decisive factor to ensure the stove works correctly. Therefore

ensure an authorised technician conducts the settings.

The list of fans in place is shown in the table:

STOVE MODEL

NO. OF FANS

EGO/STAR AIR

1

EGO/STAR COMFORT AIR

2

FIG.6