Epson EMP-X56 User Manual
Page 20

ESC/VP21 Command User's Guide for Business Projectors
20 of 25
CCAP xx
CCAP?
00 : OFF
11 : CC1
12 : CC2
13 : CC3
14 : CC4
21 : TEXT1
22 : TEXT2
23 : TEXT3
24 : TEXT4
6100
6110
Select Closed Caption
00 : OFF
11 : CC1
12 : CC2
83/822/83+/822+
400W
G5350/G5300/G5150/
G5100/G5200W/G5000
FLWARNING xx
FLWARNING?
00 : ON
01 : OFF
6100
6110
Display setting of warning
time of Air filter
FLTIME x1 x2
x1 Object of setting
00 : All objects
01 : Object 1
02 : Object 2
03 : Object 3
x2 Set time
0 : 1-100 (100H)
1 : 101-200 (200H)
I
14 : 1401-1500 (1500H)*
6100
6110
Setting of use time of air filter
*The maximum value
depends on the kind of the
air filter and the upper bound
value is different.
FILTER?
0-65535
6100
6110
Acquisition of use time of air
filter
Set commands
Get commands
Parameter for set
(Return code for get)
Models
Function