- 24 -

This system can be controlled from the PC by connecting the RS-485 terminal on the 9-pin

Terminal Block to the PC via an RS-485 converter.

Make the connection as shown below.

Each camera can be set for the ID address via a 10-pin DIP Switch located on the bottom so

that a selected camera can be controlled.

Up to 223 Cameras can be controlled from one PC.

To raise the reliability, connect the DATA (+)and the DATA (-) with a twist pair cable.

To protect this system and the PC, be sure to turn OFF the POWER switches of all units

before starting the connection.

9. RS-485

Communication specifications

• Communication mode: Synchronous half duplex

• Communication speed: 9600bps

• Start bit:

1 bit

• Stop bit:

1 bit

• Parity bit:

None

Pin assignment

Terminal name

+IN

-IN

+OUT

-OUT

GND

Signal name

DATA (+)

DATA (-)

DATA (+)

DATA (-)

GND

Function

+ side: Inputs the transmitted/received

- side: Inputs the transmitted/received

+ side: Outputs the transmitted/received data.

- side: Outputs the transmitted/received data.

Grounds.

+

-

+

-

GND

1

ND

OUT

If you need the data format specifications and the command table, please contact our