Malfunctions, causes and solutions, 1 malfunctions during operation – Silvercrest SKMH 1100 A1 User Manual
Page 101
SKMH 1100 A1
99
11. Malfunctions, causes and solutions
11.1 Malfunctions during operation
Malfunction
Cause
Solution
Appliance fails to start
Blender jug 6 is not correctly
positioned
Position the blender jug 6 correctly
(see “7.3 Positioning the blender
jug” on page 88)
Lid 25 of the blender jug 6
is not correctly positioned
Position the lid 25 correctly (see
“7.5 Positioning the lid of the
blender jug” on page 89)
No power supply
Check the plug and if necessary
also the fuse
Incorrect power supply
Make sure to use the correct power
supply (see “6.1 Connecting the
power supply” on page 85)
There is liquid
underneath the
appliance
Blade assembly 20 is not
correctly seated and is
leaking
Position the blade assembly 20
correctly (see “7.2 Inserting and
removing the blade assembly” on
page 88)
The seal of the blade
assembly 19 is defective
Install a new seal 19 (see
“10.6 Ordering seals” on
page 98)
Liquid has escaped from the
blender jug 6 and has
drained through the base
unit’s overflow hole 17 onto
the underlay (see
“6.9 Overflow” on
page 87)
When blending liquids on level 10
or using the pulse button 9, do not
exceed a quantity of 1 litre in the
blender jug 6, otherwise liquid may
spray out. At speeds lower than 10,
the blender jug may contain up to
2 l.
Liquid is leaking from the
lid 25 of the blender
jug 6
Seal 24 is not correctly
positioned
Position the seal 24 correctly (see
“10.3 Cleaning the accessories” on
page 97)
Seal 24 is defective
Install a new seal 24 (see
“10.6 Ordering seals” on
page 98)
RP93471 Küchenmaschine mit Heizung LB5 Seite 99 Donnerstag, 14. August 2014 3:36 15