10. Position the ceiling cover over the downrod. Be
sure the cover is oriented correctly, with the large
opening at the top (Figure 5B).
11. Reinstall the hanger ball on the downrod
as follows. Route the motor leads through the
hanger ball and slide the hanger ball over the
downrod (Figure 5B). Install the pin through the
holes at the top of the downrod and slide the
hanger ball up the downrod, aligning the ball so the
pin is captured in the groove in the top of the
hanger ball. Pull the hanger ball up tight against the
pin and securely tighten the setscrew in the hanger
ball. A loose setscrew could create fan wobble.
12. Screw in four 60-watt (maximum) candelabra base
lamps in the housing sockets (Figure 6B). Grasp
the sockets and pivot them until the lamp bulbs are
even with the top of the housing as shown. This will
provide the optimum lighting effect.
13. The blue, black and white leads exiting the
downrod are 80-inches long. Before installing fan,
measure up approximately 6 to 9-inches above
the ball/downrod assembly. Cut off excess leads
and strip back insulation 1/2-inch from end of
leads.
NOTE: If you are installing your fan with a SR330
Remote Control or SW350 Wall Control, Do Not
Cut Terminal Off of the Yellow Lead.
(See SECTION A.)
14. Securely attach the hanger bracket to the outlet
box using the two screws supplied with the outlet
box (Figure 8B).
11
TOP OF
HOUSING
CANDELABRA
BASE LAMP
SOCKET
Figure 6B
DOWNROD
PIN
HANGER BALL
CEILING COVER
Figure 5B
IMPORTANT
A.
If you have installed an 18” or longer downrod
and are planning to install the decorative
support rods assembly, proceed to
“INSTALLATION OF DECORATIVE SUPPORT
RODS ASSEMBLY” on page 14. After you have
installed the decorative support rods
assembly, continue with the following
installation procedures.
B.
If you have installed the 4-1/2” downrod,
continue now with the following procedures.
It is critical that the pin in the hanger ball is properly
installed and the setscrew securely tightened.
Failure to verify that the pin and setscrew are
properly installed could result in the fan falling.
WARNING
!
The outlet box must be securely anchored and capable
of withstanding a load of at least 50 lbs.
WARNING
!
The fan must be hang with at lease 7’ of clearance from
floor to blades (Figure 7B).
WARNING
!
AT LEAST
7'
FLOOR
Figure 7B
To reduce the risk of fire, electric shock, or personal
injury, mount fan to outlet box marked acceptable for
fan support, and use screws supplied with outlet
box. Most outlet boxes commonly used for support
of light fixtures are not acceptable for fan support
and may need to be replaced. Consult a qualified
electrician if in doubt.
WARNING
!
Hanger bracket must seat firmly against outlet box. If
the outlet box is recessed, remove wall board until
bracket contacts box. If bracket and/or outlet box are
not securely attached, the fan could wobble or fall.
WARNING
!
TWO SCREWS
SUPPLIED WITH
OUTLET BOX
HANGER
BRACKET
TAB
OUTLET
BOX
Figure 2
Figure 8B