Note: To convert a B-Vent to a Direct Vent,

remove the air intake plug, remove the

spill switch assembly and re-install the flue

slider bottom plate, re-install the jumper

onto the thermocouple wire, re-install the air

intake cover plates, install the proper venting,

re-install the screw into the draft tube at the
front top of the unit.

Figure 38: Air Intake Cover Plates.

V

ENTING

F

IREPLACE

I

NSERTS

:

The ENVIRO Sonnet may be installed and vented into any solid fuel fireplace that has been installed

in accordance with the National, Provincial/State and local building codes and has been constructed of

non-combustible materials. Before starting, refer to I

NITIAL

I

NSTALLATION

- P

REPARING

Y

OUR

S

ONNET

F

OR

I

NSTALLATION

and I

NITIAL

I

NSTALLATION

- C

ONVERTING

A D

IRECT

V

ENT

F

IREPLACE

T

O

A B-

VENT

F

IREPLACE

. Please

reference the information in Table 5 and Figures 39, 40, and 43.
An approved chimney liner and rain cap must be used. A throat connector or flashing must be installed

to ensure a tight seal, top performance, safety and efficiency. Carefully follow the manufacturer’s

instructions that accompany the chimney liner kit. Use listed B-Vent or Flexmaster double walled

aluminum flex vent.
If necessary, remove the vent collar plate from the top of the insert and connect it securely to the liner

with sheet metal screws and/or hose clamps. Check for any tears in the liner at this point. IMPORTANT:

The screws that hold the vent collar plate in its approved position must be installed.

Initial Installation

QUALIFIED INSTALLERS ONLY

3. Remove screw from draft tube and remove air intake covers.

a) Remove the glass door as shown in the M

AINTENANCE

A

ND

S

ERVICE

- G

LASS

D

OOR

R

EMOVAL

.

b) Using a T-20 screwdriver remove the screw that is in the draft tube pointed at in Figure 30.

c) Remove the two (2) air intake covers below the firebox (refer to Figure 38), they can be pried out

using a flat head screwdriver.

d) Install door.
4. Test fire the appliance and ensure proper operation. A venturi adjustment (Figure 8) could be required

to achieve an efficient flame, refer to Figure 79. Improper operation or adjustment could result in

Carbon Monoxide production causing personal injury or property damage.

Provide for proper and adequate venting

and air supply for this appliance in

accordance with the tables in the current

National Fuel Gas Code, Z223.1/NFPA 54

or the CSA B149.1.
NOTE: If the Sonnet unit is pulled out

of its installation, and the vent air intake

system is disconnected for any reason,

ensure that the vent-air intake pipes are

re-sealed with high-temperature sealant

or silicone and reconnected with three

(3) sheet metal screws evenly spaced.

2ft (0.6m)

Minimum

3ft (0.9m)

Minimum

Within

10ft (3m)

Roof ridge or

any other portion

of a building

Figure 39: Roof Clearances.