Mounting, Changing the bulb, Maintenance and cleaning – Livarno HALOGEN CEILING LIGHT User Manual

Page 32

background image

32 GB

Guarantee and Service / Disposal / Declaration of conformity / Manufacturer

Prior to ... / Mounting / Changing the bulb / Maintenance and Cleaning

Familiarise yourself with all instructions and

diagrams in this manual, as well as with the
luminaire before installation.

Before installation, ensure that the cable that the

luminaire will be attached to is de-energised.
To do this, remove the fuse or switch off the
circuit breaker in the fuse box (0 position).

Use the voltage tester to verify de-energised

status.

Mounting

Remove the visible screws

5

on the side of the

connection housing

6

and take off the mount-

ing bracket

4

on the rear (see fig.).

Use the slotted holes intended for the mounting

bracket

4

to mark the bores.

Drill the fastening bores (∅ approx. 6 mm, depth

approx. 40 mm). Ensure that you do not damage
the supply line.

Introduce the dowels

7

into the bores. Fasten

the mounting bracket

4

with the provided

screws

8

.

Next, pull the fabric tubes over the mains cable

10

.

Now connect the connection cable of the light

to the mains connection cable

10

using the ter-

minal block

9

(see fig.).

Ensure that each wire of the mains connection
cable (external) is properly connected in the
correct place: live wire, black or brown =
symbol L, neutral wire, blue = symbol N, Now
connect the protective earth wire (green-yellow)
with the earthing lug which is indicated in the
connection housing

6

.

Use the screws

5

to fasten the luminaire to

the mounting bracket

4

.

Use a clean, lint-free cloth to insert a bulb

2

.

Push the bulb

2

carefully into the socket.

Check for correct fitting.
Screw the lamp lens

1

onto the spotlight

head

3

in a clockwise direction.

Your luminaire is now ready for operation.

Changing the bulb

CAUTION! DANGER OF ELECTRIC SHOCK!

To replace the bulb, first disconnect the luminaire
from the mains circuit. To do this, remove the fuse
or switch off the circuit breaker in the fuse box
(0 position).

CAUTION! DANGER OF BURN INJURIES!

Allow the luminaire to cool completely.

Replace the bulb

2

only after it has fully cooled.

Turn the lamp lens

1

from the spotlight head

3

in an anticlockwise direction.

Remove the defective bulb

2

carefully out of

the socket.

Use a clean, lint-free cloth to replace a bulb.

Only use 220-240 V ∼ halogen light bulbs with
a G9 base and a maximum of 28 watts.

Insert the new bulb

2

into the socket. Check

that it sits correctly.

Screw the lamp lens

1

onto the spotlight

head

3

in a clockwise direction.

Maintenance and Cleaning

CAUTION! DANGER OF ELECTRIC SHOCK!

To clean the luminaire, first disconnect it from the
mains circuit. To do this, remove the fuse or switch
off the circuit breaker in the fuse box (0 position).

CAUTION! DANGER OF ELECTRIC SHOCK!

For electrical safety reasons, never clean the lumi-
naire with water or other fluids nor immerse it in
water.

CAUTION! DANGER OF BURN INJURIES!

Allow the luminaire to cool completely.

Do not use solvents, benzene or similar sub-

stances. They could damage the luminaire.

Use a duster or brush for cleaning.