5.1. Make sure the heater plug is disconnected from the mains supply before any cleaning is attempted. Also allow the heater to cool
completely.
DO NOT use water or other liquids, or harsh abrasive cleaners to clean the heater. DO NOT touch the carbon fibre elements
with fingers as this may damage the tube.
5.2. Clean the exterior with a soft damp cloth with some mild detergent.
5.3. To replace any of the elements or lamps, contact your authorised
Sealey dealer.
5.4. To change the remote batteries, press down and push back the
battery cover (fig.2), remove old batteries and replace with two
new AAA batteries.
WARNING! DO NOT mix old and new batteries and dispose of
old batteries in accordance with local authority regulations.
Model No
IWMH1809R
IWMH1809LR
Power:
1800W
1800W
Input supply:
230V 50Hz 13A
230V 50Hz 13A
Dimensions (W x H x D): 650 x 200 x 240mm
890 x 200 x 240mm
Minimum Height:
1800mm
1800mm
LED Quantity:
-
40
3. INSTALLATION
3.1. WALL MOUNTING (fig.1).
IMPORTANT!
The heater should always have a minimum
clearance of 30cm from a ceiling and at least 1m from any
object.
Ensure that mounting surface is capable of supporting the
weight of the heater.
3.2. Using wall bracket (2) as a template, drill the wall and insert
suitable wall fixings.
NOTE: Minimum height for lower fixing
screws 1600mm.
3.3. Secure the metal bracket to the wall using screws (3).
3.4. Attach heater support (5) to the wall bracket (2) using screw (6),
washers (7) and nut (8).
3.5. Slide the heater (1B) onto the heater support (5A) and secure
using screw (9).
3.6. Adjust the angle of heater to direct heat where required.
2. INTRODUCTION & SPECIFICATION
A totally dry heat, no condensation, no gas, no fumes and no smell. Reaches maximum heat output within seconds of being turned on. Highly polished
aluminium reflector for maximum heat efficiency. Adjusts horizontally through 25° while mounted. Controlled by push on/off switch or remote control,
allowing unit to be on full, half or low power. IWMH1809LR features two banks of 20 LED's for added lighting in evenings and dark areas. Ideal for
industrial or domestic applications. Suitable for indoor and outdoor use, if weather protected (IP24 rated).
4. OPERATION
5. MAINTENANCE
WARNING! Ensure you read, understand and apply the safety instructions in Section 1 before using the heater.
4.1. Ensure the heater is at least 1m from any object. The heater can be tilted from 0° to 25°, set it to the required angle before switching the
heater on.
4.2. Plug in the heater and switch it on using the ON/OFF Heat button on the base of the heater, a blue indicator light will flash indicating that
the unit is in stand by mode. Press either the ON/OFF button on the control panel or on the remote to turn the heater on, the blue indicator
light will be on.
4.3. On models fitted with LED lights, switch on the lights by using the ON/OFF Light button on the base of the unit, a blue indicator light will
flash indicating that the unit is in stand by mode press the button again or the button on the remote to switch on the LED's, the blue
indicator light will be on.
4.4. When the heater or lights are no longer required, switch off using the appropriate ON/OFF button(s) on the base and unplug the unit.
NOTE: When switching off using the remote, the heater and lights will be in stand by mode.
4.5. The heater has a built in tilt switch safety mechanism that switches off the unit if it is tilted beyond 25° either forwards or backwards. This
prevents fire in the event of the unit being knocked over. If the unit does not turn on again when returned to the vertical, tip it approximately
25° in the opposite direction until you hear the internal switch operate. As the heater switches on return it to the vertical position.
fig.1
fig.2
Environmental Protection
R
ecycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to a
recycling centre and disposed of in a manner which is compatible with the environment.
When the product becomes completely unserviceable and requires disposal, drain off any fluids (if applicable)
into approved containers and dispose of the product and the fluids according to local regulations.
WEEE Regulations
Dispose of this product at the end of its working life in compliance with the EU Directive on
Waste Electrical and Electronic Equipment (WEEE). When the product is no longer required, it must be disposed
of in an environmentally protective way. Contact your local solid waste authority for recycling information.
Battery Removal: see section 5.4. for battery removal details.
Under the Waste Batteries and Accumulators Regulations 2009, Jack Sealey Ltd are required to inform potential
purchasers of products containing batteries (as defined within these regulations), that they are registered with Valpak’s registered
compliance scheme. Jack Sealey Ltd’s Batteries Producer Registration Number (BPRN) is BPRN00705
.
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
IMPORTANT: No liability is accepted for incorrect use of this product.
WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
INFORMATION: For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.
01284 757500
01284 703534
Sole UK Distributor, Sealey Group,
Kempson Way, Suffolk Business Park
,
Bury St. Edmunds, Suffolk,
IP32 7AR
www.sealey.co.uk
© Jack Sealey Limited
IWMH1809R, IWMH1809LR Issue: 4(L)- 11/06/14
Original Language Version