beautypg.com

Fig.3 fig.4, Maintenance 5 . troubleshooting – Sealey SDH50 User Manual

Page 3

background image

fig.3

fig.4

Drain plug and continuous

draining hose connection

3.4.3

remove the plug from the bottom right hand side of the tank (fig.3) and

attach a suitable length hose It should have an inner diameter of 5/8"

and secure with a hose clip.

3.4.4 thread the hose through the hole in the bottom right hand side of the

base of the unit, insert the tank ensuring that the hose is not kinked.

3.4.5 continue to use the dehumidifier as normal.

4.1

Cleaning air filter

the dehumidifying capacity is lowered when the air cleaning filter

becomes clogged.

4.1.1 open the front door of the unit.

4.1.2 Lift up the filter element from the bottom as shown in fig.4 and lift

out of the holder.

4.1.3 to dislodge the dust from the filter, use a vacuum cleaner or tap it

lightly.

4.1.4 If the filter is very dirty, wash it carefully in water with a neutral

detergent, then rinse well with clean water and leave until dry.

4.1.5 to refit the air filter locate the top of the element into the locating

bracket at the top of the door and then locate the lower section into

the lower bracket.

4.1.6 close the door of the dehumidifier.

4.2

storage

4.2.1 unplug the unit, bundle the power cord, and hang the bundled cord

at the back of the unit.

4.2.2 remove the water collection tank and empty the water out of it.

remove the tank cover and wash the inside of the tank with clean

water. the tank may be scratched if it is scrubbed strongly with a

brush. Do not remove the float lever from the tank. Wipe off the

water on the outside of the tank with a cloth. refit the tank cover

onto the tank and replace the tank in position.

4.2.3 clean the air filter (see 4.1).

4.2.4 When the unit is to be stored for a long time, wipe the dehumidifier

over with a dry soft cloth. to remove dirt, wipe over with a very

slightly dampened cloth (never use a wet cloth for cleaning the

controls). to avoid deformation or cracking, do not use benzine,

thinner or liquid cleaners.

4.2.5 When storing, place in a safe, dry, childproof location. stand the unit

upright and avoid exposure to direct sunlight.

4. maintenanCe

5 . trOuBleshOOtinG

Problem

Cause

remedy

Will not run

switch is not “on”

switch “on”

unit is not plugged in

Insert plug

fuse blown

replace fuse

Water tank full

Empty water tank

Dehumidifier inefficient

filter blocked

Clean filter

Inlet or outlet vents restricted

remove restriction

Doors or windows open

close openings

refrigerant leak

contact sealey dealer

Water leaking from unit

Dehumidifier is not level

Adjust position of dehumidifier

Reservoir float not shutting down unit

contact sealey dealer

Error codes

Problem

E1

Humidity sensor faulty

E2

refrigerant sensor faulty

NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

imPOrtant: no liability is accepted for incorrect use of this product.

WarrantY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.

infOrmatiOn: for a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.

01284 757500

01284 703534

[email protected]

sole uK distributor, sealey Group,

Kempson Way, suffolk Business Park

,

Bury st. Edmunds, suffolk,

IP32 7Ar

www.sealey.co.uk

Web

email

Original Language Version

sDH30, sDH50 Issue: 2 - 10/02/10

This manual is related to the following products: