beautypg.com

Electrolux EKC6046 User Manual

Page 35

background image

35

CONNECTING TO THE MAINS TERMINAL


Warning: This appliance must be earthed.

• We recommend you use a new length of 6mm

2

twin core and earthed cable to ensure your safety.

Make connection as shown in Fig. 7 by

proceeding as follows:-

Preform wires to the appropriate shape to suit

fitting into the mains terminal block.

Strip inner insulation on wires using wirestrippers.

Twist the bared wires using pliers.

Cut bared wires 10mm away from the end of the

inner insulation. Where uninsulated Earth wires are

used ensure they are suitably sheathed to leave

10mm bare wire to fit into the terminal.

Clamp bare wires into the relevant terminal and

check they are held by tugging each one in turn.

Clamp the mains cable securely ensuring 5mm of

the outer insulation is inside the terminal block and

that the wires are not taught but not so slack as to

cause any fouling. See Fig. 7.

Place fuse/miniature circuit breaker in circuit and

switch on at mains.

CHECKING ELECTRICAL CONNECTIONS

Correct electrical connection can be confirmed when

switching on the appliance as the timer will be flashing.
NOTE: HOUSE CIRCUIT

Earth leakage and continuity tests must be carried out

before the appliance is connected to the mains supply

and re-checked after fitting.

CONNECTING TO A HOB OR COOKER

POINT

Either follow in general terms the instructions for

connecting to the terminal block or refer to the hob

suppliers installation instructions.

Feed the cable through the cabinet and arrange to

route the cable away from the appliance which

may become hot.

Fig.7