beautypg.com

Installation instructions – Electrolux EKC6046 User Manual

Page 31

background image

31

INSTALLATION INSTRUCTIONS

WARNINGS

This appliance must be installed by a qualified

electrician/competent person. Safety may be

impaired if installation is not carried out in

accordance with these instructions.

This appliance must be earthed.

Do not remove the screws from the earth tab

extending from the oven mains terminal block

(Fig. 1).

Before connecting the appliance make sure that

the voltage of your electricity supply is the same

as that indicated on the rating plate. This is

situated on the lower front frame of the appliance

and can be seen upon opening the door.

Alternatively the rating plate may also be found on

the back or top of some models (where

applicable).

Do not alter the electrical circuitry of this

appliance.

THINGS TO NOTE

This appliance is designed to be fitted in cabinets

of the recommended dimensions as shown (Fig.3).

If your cabinet interior dimension is between 565-

570mm the oven may still be fitted. However, a

minor modification to the cabinet will be required

to reduce the aperture size down to 560-565 mm,

to allow the product to be securely screwed into

the cabinet.

The dimensions given provide adequate air

circulation around the unit within the cabinet,

ensuring compliance with BS EN60-335.

Enquiries regarding the installation of the cooker

point, if required, should be made to your Regional

Electricity Company to ensure compliance with

their regulations.

The appliance socket switch should be outside the

cabinet but within 2m of the appliance to make it

accessible to switch off the appliance in case of an

emergency.

To protect the hands, wear gloves when lifting the

oven into its housing.

Do not lift the appliance by the handles.


NOTE: HOUSE CIRCUIT

Earth leakage and continuity tests must be carried out

before the appliance is connected to the mains supply

and re-checked after fitting.

Fig.1