5-1

L2401EA

ELECTRICAL ADJUSTMENT INSTRUCTIONS

General Note:
"CBA" is abbreviation for "Circuit Board Assem-
bly."

NOTE:

Electrical adjustments are required after replacing
circuit components and certain mechanical parts.
It is important to perform these adjustments only
after all repairs and replacements have been com-
pleted.
Also, do not attempt these adjustments unless the
proper equipment is available.

Test Equipment Required

1. NTSC Pattern Generator (Color Bar W/White

Window, Red Color, Dot Pattern, Gray Scale,
Monoscope, Multi-Burst)

2. DC Voltmeter
3. Oscilloscope: Dual-trace with 10:1 probe,

V-Range:0.001~50V/Div,
F-Range: DC~AC-60MHz

4. Plastic Tip Driver
5. Remote control unit: Part No. NE122UD
6. DC power supply 13.2V/5A

How to make Service remote control unit:

1. Prepare normal remote control unit.

(Part No. NE122UD --- [ 6420FE ])
(Part No. NE154UD, NE142UD, N0108UD,
N0132UD, NE116UD, NE153UD, NE141UD,
NE122UD, or NE121UD --- [ EWF2004 ])
Remove 3 Screws from the back lid. (Fig. 1-1)

2. Added J1 (Jumper Wire) to the remote control CBA.

(Fig. 1-2)

How to set up the service mode:

Service mode:

1.

Use the service remote control unit.

2.

Turn the power on. (Use main power on the TV
unit.)

3. Press "SLEEP" button on the service remote con-

trol unit. Version of micro computer will display on
the CRT. (Ex: 058-0.06)

4.

Check the display on the lower left is "2641" and if
it is not "2641," set it at "2641" according to "2. Ini-
tial Setting."

1. +B Adjustment

Purpose: To obtain correct operation.

Symptom of Misadjustment: The picture is dark and
the unit does not operate correctly.

Note: TP601, TP300(GND), VR661 --- Main CBA
1. Connect DC Volt Meter to TP601 and TP300(GND).
2. Adjust VR661 so that the voltage of TP601 becomes

+114±0.5V DC.

SCREWS

REMOTE CONTROL UNIT

Fig. 1-1

J 1

Fig. 1-2

REMOTE CONTROL CBA

Test Point

Adj. Point

Mode

Input

TP601(+B)

TP300(GND)

VR661

---

---

Tape

M. EQ.

Spec.

---

DC Voltmeter

+114±0.5V DC.