Problem Cause Solution

1. Auger not turning

1. Loose set screw
2. Bad gear motor
3. Foreign matter in auger
4. Vacuum

sensor

1.

Tighten setscrew on collar

2. Replace auger motor
3. Remove pellets and object
4. Check exhaust blower

2. Smoke smell or dust in

house

1. Improper

exhaust

connection

1.

Check all connections for leaks especially the
exhaust blower connection; Seal with
silicone, hose clamp or aluminum tape.

3. Room air blower not

operating

1. Loose

sensor

2. Bad

blower

1.

Tighten connection on sensor

2. Replace

blower

4. Exhaust blower not

operating

1. Loose

connection

2. Bad

blower

1.

Check connection at control board

2. Replace

blower

5. Lazy

fire

– Fire burns with

a lazy, orange flame
and/or fuel builds up in the
burnpot. Glass may
become dirty.

1. Control board settings
2. Bad

exhaust

blower

3. Excessive pellet moisture
4. Excessive

ash

5. Low

quality

pellets

6. Flue or intake is restricted.
7. Glass door not shut and

sealed tightly.

8. Ash removal plates are

not pushed completely in.

9. Exhaust fan is not running

or stove not venting
properly.

10. Moisture content above

15%.

11. Blockage inside stove and

exhaust pipes.



12. Feed rate is too high for

fuel.

13. Inadequate combustion air

available.

1.

Review board settings

2. Replace

blower

3. Keep pellets inside
4. Clean

unit

5. Use premium pellets
6. Inspect flue and intake for obstructions.
7. Adjust door handle or replace gasket if

necessary.

8. Verify ash removal plates are pushed

completely in.

9. Verify that exhaust fan is running and venting

properly. If not, check connection and clean
or replace.

10. Allow fuel to dry or mix with some wood

pellets.

11. Check inside stove and exhaust pipes for

blockage. Tap inside walls of Firebox, clean
behind the lower access plates (located on
the back inside wall, next to the burnpot);
clean burnpot and Firebox vent holes above
firebrick panel.

12. Reduce heat setting.

13. Outside combustion air is mandatory.

(Our Part PU-OAK is acceptable).

6. Blown fuse (6 AMP)

1. Power surge
2. Exposed

wire


3. Electric motor shorting or

bound up

1.

Replace fuse; use surge protector

2. Check for exposed or frayed wire and loose

connections

3. Check motors and blowers for obstructions

or lock-up

7. High pellet consumption

1. Low quality pellets
2. Board out of adjustment

1.

Use premium fuel

2. Check control board settings

8. Squeaking

noise

1. Build

up

in

tube

2. Blower

noise

1.

Remove auger and clean

2. Remove

and

oil

blower

9. Pinging or rattling noise

1. Foreign material
2. Loose set screw

1. Check blower for material
2. Check impeller blower screw


*Improper installation may cause a back draft.