IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING

CLEANING THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.

ENGLAND’S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT, OR DUE

TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH QUESTIONS.

12





























FLOOR AND WALL PROTECTION

Floor Protection

If your floor is constructed of a non-combustible material such as brick or concrete, there is no need for

floor protection. If the floor is constructed of a combustible material such as hardwood, linoleum, or carpet, then
you will be required to use floor protection between the unit and the combustible. The protection should be U.L.
approved or equal, and should be large enough to provide a minimum of six inches (6”) behind and on both
sides of the stove. The clearance in front of the stove should be at least six inches (6”). This freestanding pellet
unit will need a minimum 36” x 48” floor protector.

Wall Protection

From the rear of this stove only six inches (6”) of clearance is required to paneling, wallpaper or drywall

(we recommend more clearance for maintenance access). Six inches (6”) would be required to a sidewall.
From the corner of the stove, 4 ½” of clearance is required. Alcoves: The alcove must be a minimum of sixty-
six inches (66”) from floor to ceiling. Six inches (6”) of clearance is required from the stove to an alcove
sidewall; six inches (6”) is required to an alcove back wall.

The corn vent pipe would require the standard three inches (3”) clearance, or as recommended by the pipe

manufacturer. Normally, additional wall protection is not required with this type unit.

Illustration 1

Freestanding Pellet/Corn/Multi-fuel Installation

Caution: Follow the pipe manufacturer’s installation instructions and directions for

passing through combustible walls and ceilings. Check local codes in your area.

Our Part AC-33000

is acceptable for

through-the-wall

installation.

(We recommend 4”

for 2500+ ft.

installations, Our

Part AC-33100.)

Must have

minimum 3”

adapter before tee

for longer run.

For shorter run, tee

alone is acceptable.

Basement Installation

should be performed by

professional installer. Use

3” metal pipe and coupler

for Outside Combustion

Air. Minimum 3 ft. (3’)

clearance from ground to

the Corn Vent Exhaust

Pipe.

1.

If 3” flue pipe exceeds 15’ in length, increase to 4” flue pipe for remaining flue connections.

2.

Total flue length should not exceed 35’.

3.

Horizontal run not to exceed 4’.

4.

Floor protector required: Min. size 36” x 48”.

5.

If the total run of outside air connection exceeds 6’, if more than 2 elbows are used, or if a
basement install, use 3” metal pipe (and coupler) instead.

6.

Outside Air is mandatory for proper safe operation.