IMPORTANT! READ AND FOLLOW ALL INSTALLATION AND MAINTENANCE INSTRUCTIONS, INCLUDING

CLEANING THE UNIT AS SPECIFIED, AND REPLACING GASKETS ANNUALLY, AND PARTS AS NEEDED.

ENGLAND’S STOVE WORKS IS NOT RESPONSIBLE FOR ANY DAMAGE OR INJURY INCURRED DUE TO NEGLECT, OR DUE

TO UNSAFE INSTALLATION OR USAGE OF THIS PRODUCT. CALL TECHNICAL SUPPORT WITH QUESTIONS.

25































CIRCUIT BOARD FUNCTIONS

COMPONENT OPERATION

START OPERATION

END

Exhaust Blower
(Combustion)

Starts Immediately.

Will continue until shutdown. Shutdown will
occur when the operating temperature is below
90 degrees.

Stirrer

Three minutes after starting, the Stirrer
will begin to turn.

Will continue intermittently, as determined by the
Heat Setting, until Shutdown

Auger

When starting, the auger will begin to
turn.

The auger will continue at the feed rate
determined by the Heat Setting. NOTE: Safety
switch, Hi Limit and Vacuum Sensor must be
activated to continue proper operation.

Room Fan
(Convection)

Begins when 110 degrees is reached.

Will continue to operate until the unit cools down
to below 90 degrees. This may take from
several minutes up to an hour.

Automatic
Shutdown

If, after 15 minutes, the unit has not
reached the preset operating temp., the
unit will begin to automatically shut
down. This will be evidenced by the red
light on the Control Board.

If the timer should expire before the preset
operating temperature is achieved, resetting the
timer is possible by switching the Control Board
“OFF” and then back “ON.”

Normal Operation

If, after 15 minutes, the preset operating
temperature of 110 degrees is achieved,
normal operation will continue.

Operation will continue until either the Control
Board is turned “OFF,” or the operating
temperature falls to below 90 degrees. At this
time, the unit will default to “Automatic
Shutdown.”

Illustration 7 Control Board Diagram (Wiring)