Excell precision co., ltd – Excell Precision FM User Manual
Page 31
EXCELL PRECISION CO., LTD
.
FM User Manual
SME300000119
30
2 OP-01 RS232 / RS485 Interface Function
Setting
Parameter
Code
Function
Parameter
Description
Default
Setting
0
Display Correspondingly
1
Gross Weight
2
Net Weight
3
Tare
4
Weight Accumulation
5
Times Accumulation
RS1-00
Information
Pattern
6
Output with Date & Time
0
0
Continuous Transmission
1
Auto Transmission
2
Press or to transmit
3
Command Mode (no address)
RS1-01
Transmission
Method
4
Command Mode (with address)
0
0
1200
1
2400
2
4800
3
9600
RS1-02
Transmission
Rate
4
19200
1
0
N, 8, 1
No Parity
8 Bits Length
1 Stop Bit
1
O, 7, 1
Odd Parity,
7 Bits Length,
1 Stop Bit
RS1-03
Parity
Bit Length
Stop Bit
2
E, 7, 1
Even Parity,
7 Bits Length,
1 Stop Bit
2
0
Continuous Output
RS1-04
Unstable or
Over Load
1
Stop Output
0
0
Positive (over + 10D)
RS1-05
Auto
Transmission
Condition
1
Positive/negative
(over + 10D, under - 10D)
0
RS1-06
Command
Address
00
↓
99
Available only if RS1-01 setting is
“4”
0
0
Standard Format
RS1-07
Output
Format
1
UMC 600
0
F2
4
F1