2 OP-01 RS232 / RS485 Interface Function

Setting

Parameter

Code

Function

Parameter

Description

Default
Setting

0

Display Correspondingly

1

Gross Weight

2

Net Weight

3

Tare

4

Weight Accumulation

5

Times Accumulation

RS1-00

Information

Pattern

6

Output with Date & Time

0

0

Continuous Transmission

1

Auto Transmission

2

Press or to transmit

3

Command Mode (no address)

RS1-01

Transmission

Method

4

Command Mode (with address)

0

0

1200

1

2400

2

4800

3

9600

RS1-02

Transmission

Rate

4

19200

1

0

N, 8, 1

No Parity

8 Bits Length

1 Stop Bit

1

O, 7, 1

Odd Parity,

7 Bits Length,

1 Stop Bit

RS1-03

Parity

Bit Length

Stop Bit

2

E, 7, 1

Even Parity,

7 Bits Length,

1 Stop Bit

2

0

Continuous Output

RS1-04

Unstable or

Over Load

1

Stop Output

0

0

Positive (over + 10D)

RS1-05

Auto

Transmission

Condition

1

Positive/negative

(over + 10D, under - 10D)

0

RS1-06

Command

Address

00

99

Available only if RS1-01 setting is

“4”

0

0

Standard Format

RS1-07

Output

Format

1

UMC 600

0

F2

4

F1