beautypg.com

Chapter 6> special function, 1 animal scale function setting 2, Excell precision co., ltd – Excell Precision FM User Manual

Page 22: Example

background image

EXCELL PRECISION CO., LTD

.

FM User Manual

SME300000119

21

32 Times

30d

10d

WT

T

32次

重量保持

取消重量保持

Special Function

6-1 Animal Scale Function Setting

2

CFN-05 = 1
(Animal Scale Mode1: No weight display under unstable status)

When no any object is on the platter, the screen will display:

When the object is on the platter, after weight has been measured, the screen will
display:

If the display weight value keeps being lower than zero plus 10d, the screen will
display:

2

CFN-05 = 2

(Animal Scale Mode 2: Weight display weather under unstable or
stable status)

When the weight value reaches the range of CFN-06 and CFN-07 setting, the screen
will keep displaying the weight value.

When the weight value is over the range of CFN-06 and CFN-07 setting, the screen will
display the normal weight measurement.

Example:

CFN-06=30 CFN-07=2

.

Weight Holding

Weight Holding Cancellation