Remove the two (2)

wood screws (one

on either side of the

unit) to remove the

unit from the pallet.

Installation

R

ATING

L

ABEL

L

OCATION

:

The rating label is located on the inside of the ash pan cover.

D

ECIDING

W

HERE

TO

L

OCATE

YOUR

P

ELLET

A

PPLIANCE

:

1. Check clearances to combustibles.

2. Do not obtain combustion air from an attic, garage or any unventilated space. Combustion air may

be obtained from a ventilated crawlspace.

3. Do not install the stove in a bedroom.

4. You can vent the stove through an exterior wall behind the unit or connect it to an existing masonry

or metal chimney (must be lined if the chimney is over 15 cm (6”) diameter, or over 180 cm² (28

inches²) cross sectional area). An interior vent can be used with approved pipe passing through the

ceiling and roof.

5. Locate the stove in a large and open room that is centrally located in the house. This will optimize

heat circulation.

6. The power cord is 2.43 m (8 feet) long and may require a grounded extension cord to reach the

nearest electrical outlet.

R

EMOVING

P

ELLET

S

TOVE

F

ROM

P

ALLET

:

1. Remove the right and left hand cabinet

sides by loosening the three (3) T-20 Torx

screws on the back of the each panel.

2. Remove the one (1) screw located on the

front of the cabinet side, behind the top

louvers and one (1) screw behind the ash

door.

3. Remove the two (2) wood screws that are

holding the bottom of the stove to the

pallet.

4. Close the side panels.

Figure 1: Screws to take out to remove stove from pallet.