Installation, Rating label location, Deciding where to locate your pellet appliance – Enviro 50-1574 User Manual
Page 6: Removing pellet stove from pallet
Remove the two (2)
wood screws (one
on either side of the
unit) to remove the
unit from the pallet.
Installation
R
ATING
L
ABEL
L
OCATION
:
The rating label is located on the inside of the ash pan cover.
D
ECIDING
W
HERE
TO
L
OCATE
YOUR
P
ELLET
A
PPLIANCE
:
1. Check clearances to combustibles.
2. Do not obtain combustion air from an attic, garage or any unventilated space. Combustion air may
be obtained from a ventilated crawlspace.
3. Do not install the stove in a bedroom.
4. You can vent the stove through an exterior wall behind the unit or connect it to an existing masonry
or metal chimney (must be lined if the chimney is over 15 cm (6”) diameter, or over 180 cm² (28
inches²) cross sectional area). An interior vent can be used with approved pipe passing through the
ceiling and roof.
5. Locate the stove in a large and open room that is centrally located in the house. This will optimize
heat circulation.
6. The power cord is 2.43 m (8 feet) long and may require a grounded extension cord to reach the
nearest electrical outlet.
R
EMOVING
P
ELLET
S
TOVE
F
ROM
P
ALLET
:
1. Remove the right and left hand cabinet
sides by loosening the three (3) T-20 Torx
screws on the back of the each panel.
2. Remove the one (1) screw located on the
front of the cabinet side, behind the top
louvers and one (1) screw behind the ash
door.
3. Remove the two (2) wood screws that are
holding the bottom of the stove to the
pallet.
4. Close the side panels.
Figure 1: Screws to take out to remove stove from pallet.
6