Thermostat installation, Optional slider/damper installation, Installation – Enviro 50-1574 User Manual
Page 20
Installation
T
HERMOSTAT
I
NSTALLATION
:
1. Install the wall thermostat (12 or 24 Volt rated) in a location that is not to close too the unit but will
effectively heat the desired area.
2. Connect the Thermostat or Timer using an 2 x 18 gauge wire from the unit to the thermostat.
O
PTIONAL
S
LIDER
/D
AMPER
I
NSTALLATION
:
If the unit has been placed in the HI / LOW mode, the unit
will be taken to a low or idle setting when the thermostat
is not calling for heat. When the thermostat calls for
heat, the unit will go to the setting that is displayed on
the control board Heat Indicator. If the heat in the room
becomes to great, the high limit switch may turn the
stove off and the switch will have to be manually reset.
To reset the high limit switch, remove the right cabinet
side. The switch is found behind the control panel. Avoid
setting off the high limit switch.
Slider damper
rod and knob
7
/
16
" Nut
7
/
16
" Clinching Nut
Slider damper plate
1. To install the OPTIONAL slider damper rod, remove the left cabinet
side and locate the slider damper plate. Install the
7
/
16
” (11mm)
nut onto the slider damper rod, thread all the way to the end of
the threads on rod.
2. Slide rod through the hole in the slider damper plate and install
the
7
/
16
” (11mm) clinching nut onto the rod and tighten completely
onto the slider damper plate.
3. Re-install the cabinet side. Install the black knob on the end of the
rod. Check slider damper for smooth operation.
Slider/
Damper
Knob
NOTE: NOT APPLICABLE FOR GERMANY AND
NEW ZEALAND
If you wish to adjust the slider damper externally (NOT
REQUIRED), please follow the instructions below.
Figure 24: Slider/Damper Assembly.
Figure 25: Slider/Damper Knob.
20
Figure 23: Thermostat wire placement.