Epson Perfection 610 User Manual
Page 9
EPSON Perfection 610
Revision B
Product Description
Specifications
9
Number of hubs:
This device must be in the Tier 1 or 2 with a
recommended USB cable.
(Tier 1: Host - this device, Tier 2: Host - Hub -
this device)
Light source:
White cold cathode fluorescent lamp
Option:
None
Operate switch:
None
LED indicator:
None
Start button:
Ease of use with Page Manager
Scanning time:
Color A4, Pentium 300MHz
300 dpi: 60 seconds
600 dpi: 280 seconds
ELECTRICAL SPECIFICATIONS
Rated voltage:
AC100-120V or AC220-240V
Input voltage:
AC 100-120V
±
10% or AC 220-240V
±
10%
Rated current:
0.5A (Input AC 100V) or 0.3A (Input AC 200V)
Rated frequency range:
50-60Hz
Input frequency range:
49.5-60.5 Hz
Power consumption:
Approximately 20 W
Insulation resistance:
10 M
Ω
at 500 VDC
(between AC line and chassis)
Dielectric strength:
AC 1.5kV, 1 min
(between AC line and chassis)
SAFETY, EMC, EPA
Safety:
UL1950 (UL)
CSA C22.2 No.950 (CSA)
EN60950 (VDE)
IEC950 (ROTEST, PSB)
EMC:
FCC Part15 Subpart B Class B
CSA C108.8 Class B
AS/NZS3548 Class B
CISPR Pub22 Class B
CNS13438 Class B
CE Marking:
Low Voltage Directive 73/23/EEC
EN60950
EMC Directive 89/336/EEC
EN55022 Class B
EN61000-3-2
EN61000-3-3
EN50082-1
IEC 801-2/801-3/801-4
EPA:
Energy Star Program
RESISTANCE TO ELECTRIC NOISE
Static electricity:
Panel:
10kV
Metal:
7kV / 150pF, 150
Ω
ENVIRONMENTAL CONDITIONS
Temperature:
Operating: 5
°
C to 35
°
C
Storage: -25
°
C to 60
°
C
Humidity:
Operating:
10 to 80%, no condensation
Storage:
10 to 85%, no condensation
RELIABILITY
MCBF:
10,000 cycles
OPERATING CONDITIONS
Dust:
Ordinary office or home conditions.
Extreme dust should be avoided.
Illumination:
Operation under direct sunlight or near strong
light source is not guaranteed and should be
avoided.