1.6 Error Indications
Refer to Section 1.5 for the error indications.
COMMAND ERROR
Cause:
Undefined command is detected.
Disposition:
The scanner ignores a wrong command and
parameter(s), so it keeps the current settings or
default value effective. The scanner sends
NACK and waits for the next command and
parameter(s).
Indicator:
No effect
Remedy:
Error condition is cleared when the scanner
receives a correct command.
COMMUNICATION ERROR
Cause:
Wrong procedure is detected in the interface
communication.
USB cable was removed during communication.
Disposition:
The scanner stops the ongoing job.
Indicator:
The lamp starts blinking. (The lamp goes off in
30 minutes.)
Remedy:
Turn the scanner off and then back on.
Connect the USB cable again.
Acceptable command:
None
FATAL ERROR
Cause:
The lamp is broken.
The scanner is turned on before the
transportation lock is released.
System breakdown
Disposition:
The scanner stops the ongoing job.
Indicator:
The lamp starts blinking. (The lamp goes off after
30 minutes.)
The lamp does not light up when it has blown.
Remedy:
(After the cause of the error is removed)
Turn the scanner off and then back on.
Connect the USB cable again.
Receiving of ESC@
Acceptable command:
[ESC F, ESC f, ESC @]